Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360
android app
/
iOS App/ web portal.
{
"products": [
{
"_id": "681b5eb7e558303897fc3977",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Sensors ",
"description": "Smoke Detector: A smoke detector also called a smoke alarm is a device that detects smoke, typically as an indicator of fire and issues a signal to a fire alarm system.\n\nHeat Detector: A heat detector is a fire alarm device designed to respond when the convicted thermal energy of a fire increases the temperature of a heat sensitive element. The thermal mass and conductivity of the element regulate the rate flow of heat into the element. All heat detectors have this thermal lag. Heat detectors have two main classifications of operation, “rate-of-rise” and “fixed temperature.”\n\nMultisensor Detector : Multisensor Detector comprises of both optical smoke and thermistor temperature sensors which give both a combined signal as well as a separate heat signal for improved false alarm management.\n\nDuct Detector: The Conventional Duct Smoke Detector provides early detection of smoke in the air moving through heating and ventilation (HVAC) ducts in commercial and industrial premises. Its purpose is to prevent the re-circulation of smoke from an area on fire to areas unaffected by the fire.\n\nBeam Detector : An optical beam smoke detector is a device that uses a projected beam of light to detect smoke across large areas, typically as an indicator of fire. They are used to detect fires in buildings where standard point smoke detectors would either be uneconomical or restricted for use by the height of the building. Optical beam smoke detectors are often installed in warehouses as a cost effective means of protecting large open spaces.\n\nGas Leak Detector: Gas leak detection is the process of identifying potentially hazardous gas leaks. These sensors usually employ an audible alarm to alert people when a dangerous gas has been detected.\n\nFlame Detector : Flame detection is the technology for detecting flames, using a flame detector. Flame detectors are optical equipment for the detection of flame phenomena of a fire. There are two categories of flame detection:\n\nFlame detector for the detection of a fire in a fire alarm system\nFlame scanner for monitoring the condition of a flame in a burner",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"early detection",
"fire increases",
"flame phenomena",
"optical equipment",
"detecting flames",
"dangerous gas",
"alert people",
"audible alarm",
"detect fires",
"detect smoke",
"industrial premises",
"air moving",
"combined signal",
"optical smoke",
"operation rateofrise",
"main classifications",
"rate flow",
"element regulate",
"smoke alarm",
"heat detectors",
"projected beam",
"areas unaffected",
"thermal mass",
"smoke detector",
"heat detector",
"fire beam detector",
"sensors smoke detector",
"separate heat signal",
"heat sensitive element",
"thermistor temperature sensors",
"detects smoke typically",
"large areas typically",
"convicted thermal energy",
"cost effective means",
"ventilation hvac ducts"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 12,
"imageuri": "https://bizimages.withfloats.com/actual/c4d74b55ac184dbb8eecd2ae3871f1a1.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/c4d74b55ac184dbb8eecd2ae3871f1a1.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:23:03.791Z",
"updatedon": "2025-05-07T13:23:03.792Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN//sensors-/12",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Fire Detection and Alarm",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b5e3072012f94c5cd0c02",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Addressable / Intelligent FAS",
"description": "An intelligent fire alarm system is designed to provide more efficient detection and prevention. Each intelligent device (smoke detector, heat detector, manual pull station, etc.) has its own unique “address.” If an intelligent device is transferred to an “alarm” state, it activates the fire horns and strobes. When the local fire department arrives, the control panel displays the specific device and area in which the activation occurred. (A conventional zone panel only identifies the general area of an activated device.)",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"general area",
"activated device",
"activation occurred",
"specific device",
"fire horns",
"alarm state",
"intelligent device",
"unique address",
"efficient detection",
"conventional zone panel",
"control panel displays"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 10,
"imageuri": "https://bizimages.withfloats.com/actual/40675ce2ee724cae8dd9221c373a0da4.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/40675ce2ee724cae8dd9221c373a0da4.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:20:48.95Z",
"updatedon": "2025-05-07T13:20:48.951Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN/products/addressable-intelligent-fas/10",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Fire Detection and Alarm",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b5de53a26099a76a38090",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Fire Detection and Alarm",
"description": "A fire alarm system is basically a network of initiating devices, and notification devices connected to a Fire Alarm Control Panel (FACP) which is used to alert people of an emergency in a building. Some modern fire alarm systems are remotely monitored by fire alarm monitoring companies who will decipher messages sent from the fire alarm system and decide whether to send the Fire Department, notify building owners / service companies of system troubles.\n\nWhat is an FACP\n\nA Fire Alarm Control Panel is the brains of the fire alarm system. All of the parts on a fire alarm system communicate with the FACP, which in turn decides what to do. Modern FACPs include keypads, LCD screens, and communication ports that make the system easier to work with.\n\nAn FACP is generally inside a locked red box located somewhere safe, such as an electrical room, office, or maintenance area. In some cases where there are no available rooms to install the FACP, the FACP might be located somewhere outside the building in a weather proof plastic enclosure.\n\nWhat is an Initiating Device\n\nAn initiating device is a sensor which detects things that are commonly a sign of fires and other hazards, or a switch that makes it possible for building occupants to set off the fire alarm manually when there’s an emergency none of the sensors can detect.\n\nCommon initiating device sensors include smoke detectors, heat detectors, and water flow detectors on fire sprinklers. Manual initiating devices pretty much consist of various styles of pull stations.\n\nWhat is a Notification Device\n\nA notification device, or notification appliance, is a device that tells everyone in the building the fire alarm is going off. Common notification appliances include horns / speakers (sounders), strobe lights, and various combinations of the three.\n\nUnfortunately some people are hearing impaired and other people are vision impaired. Some buildings have areas with a lot of ambient noise that makes it impossible to hear sounders. Some areas in buildings such as public restrooms amplify sound to harmful levels. Some areas such as hospital operating rooms have activities going on in them which could lead to disaster if a sudden loud annoying noise were to be made. Therefore we have notification appliances that can be seen and heard in a building.\n\nIn advanced fire alarm systems there may be what’s referred to as an EVAC system. An EVAC system is basically an intercom that will play a prerecorded evacuation plan over the loudspeakers when the fire alarm goes off, and make it possible for management to pick up a microphone and communicate with everyone in the building at once.\n\nYour fire-detection system can also:\n\nDischarge clean agent fire-suppression systems in computer rooms or clean rooms.\nActivate deluge fire systems in aircraft hangers or similarly dangerous areas.\nOpen a dry pipe sprinkler system for a pre-action suppression system.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 9,
"imageuri": "https://bizimages.withfloats.com/actual/9fe317a603964235823331fc253697d2.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/9fe317a603964235823331fc253697d2.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:19:33.065Z",
"updatedon": "2025-05-07T13:19:33.066Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN//fire-detection-and-alarm/9",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Fire Detection and Alarm",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b5cf1bc744980d54e15b4",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Deluge System",
"description": "A deluge system is similar to a pre-action system except the sprinkler heads are open and the pipe is not pressurized with air. Deluge systems are connected to a water supply through a deluge valve that is opened by the operation of a smoke or heat detection system. The detection system is installed in the same area as the sprinklers. When the detection system is activated water discharges through all of the sprinkler heads in the system. Deluge systems are used in places that are considered high hazard areas such as power plants, aircraft hangars and chemical storage or processing facilities. Deluge systems are needed where high velocity suppression is necessary to prevent fire spread.\n\nDeluge Fire Sprinkler Systems differ from conventional Fire Sprinkler Systems in the sense that all sprinkles or nozzles employed in the system are open and when water is released into the system it flows from all discharge devices. As such, this special type of system is generally found within industrial type hazards that require the application of water over a large hazard or area. The control of water is accomplished by the use of a Deluge Valve which is a device that prevents water from entering the system piping until required. A detection system which may incorporate the use of heat, smoke, or flame detectors is used to open the Deluge Valve when a fire or its products of combustion are detected. All system piping is filled with water which discharges from the open sprinklers and nozzles used in the system. In addition to the application of water some deluge systems will incorporate the use of a foam concentrate to mix with water and form a foam solution which can then provide a protective blanket of foam to help control the development of a fire.\nDeluge Fire Sprinkler systems protect extra hazard occupancies that require significant amounts of water to cool and control the growth or development of a fire. Typically they are employed on hazards that contain low flash point flammable liquids or hazards with large amounts of combustible liquids. These types of hazards may include, oil extraction processes, transformers, tank or vessel protection, distillation processes. Water or Foam Deluge systems are used in the protection of large Aircraft Hangers as one primary means of fire protection.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"open sprinklers",
"nozzles employed",
"fire protection",
"prevents water",
"water supply",
"fire typically",
"system piping",
"preaction system",
"primary means",
"combustible liquids",
"protective blanket",
"foam solution",
"foam concentrate",
"flame detectors",
"heat smoke",
"generally found",
"discharge devices",
"chemical storage",
"sprinkler heads",
"detection system",
"large hazard",
"deluge valve",
"special type",
"large amounts",
"deluge systems",
"activated water discharges",
"heat detection system",
"industrial type hazards",
"system deluge systems",
"foam deluge systems",
"require significant amounts",
"air deluge systems",
"large aircraft hangers",
"high velocity suppression"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 6,
"imageuri": "https://bizimages.withfloats.com/actual/4f5cb93e84da4ea79642107f131c9fae.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/4f5cb93e84da4ea79642107f131c9fae.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:15:29.727Z",
"updatedon": "2025-05-07T13:15:29.728Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN/products/deluge-system/6",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Sprinkler System",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b5c35944888e973c896f5",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Pre-action System",
"description": "Pre-action fire sprinkler systems employ the basic concept of a dry pipe system in that water is not normally contained within the pipes. The difference, however, is that water is held from piping by an electrically operated valve, known as a pre-action valve. Valve operation is controlled by independent flame, heat, or smoke detection.\n\nTwo separate events must happen to initiate sprinkler discharge. First, the detection system must identify a developing fire and then open the pre-action valve. This allows water to flow into system piping, which effectively creates a wet pipe sprinkler system. Second, individual sprinkler heads must release to permit water flow onto the fire.\n\nIn some instances, the pre-action system may be set up with a double interlock in which pressurized air or nitrogen is added to system piping. The purpose of this feature is two-fold: first to monitor piping for leaks and second to hold water from system piping in the event of inadvertent detector operation. The most common application for this system type is in freezer warehouses.\n\nAdvantages of using pre-action fire sprinkler systems include:\n\nThe dual action required for water release – The pre-action valve must operate and sprinkler heads must fuse. This feature provides an added level of protection against inadvertent discharge. For this reason, pre-action systems are frequently employed in water sensitive environments such as archival vaults, fine art storage rooms, rare book libraries and computer centers.\nDisadvantages of using pre-action fire sprinkler systems include:\n\nHigher installation and maintenance costs – Pre-action systems are more complex with several additional components, notably a fire detection system. This adds to the overall system cost.\nModification difficulties – As with dry-pipe systems, pre-action sprinkler systems have specific size limitations which may impact future system modifications. In addition, system modifications must incorporate changes to the fire detection and control system to ensure proper operation.\nPotential decreased reliability – The higher level of complexity associated with pre-action systems creates an increased chance that something may not work when needed. Regular maintenance is essential to ensure reliability",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"water release",
"added level",
"monitor piping",
"hold water",
"ensure reliability",
"increased chance",
"higher level",
"higher installation",
"frequently employed",
"common application",
"pressurized air",
"double interlock",
"developing fire",
"separate events",
"basic concept",
"system piping",
"fire detection",
"smoke detection",
"control system",
"system type",
"effectively creates",
"detection system",
"preaction system",
"preaction valve",
"inadvertent discharge",
"sprinkler heads",
"fire detection system",
"permit water flow",
"water sensitive environments",
"preaction systems creates",
"individual sprinkler heads",
"initiate sprinkler discharge",
"addition system modifications",
"dry pipe system",
"electrically operated valve",
"reason preaction systems",
"inadvertent detector operation",
"needed regular maintenance",
"specific size limitations",
"additional components notably",
"computer centers disadvantages",
"dual action required",
"freezer warehouses advantages",
"independent flame heat"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 5,
"imageuri": "https://bizimages.withfloats.com/actual/a2b28c13a31c434f8b0831ddd429b1d2.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/a2b28c13a31c434f8b0831ddd429b1d2.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:12:21.517Z",
"updatedon": "2025-05-07T13:12:21.518Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN/products/pre-action-system/5",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Sprinkler System",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b5d2a701ce9d7e115dce8",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Water Spray systems",
"description": "Water spray nozzles are designed to spray water directly onto the hazard surface via a series of nozzles with a carefully predetermined spray pattern. They are suitable for a variety of special hazards including transformer, turbines and combustible liquid hazards and systems can be individually tailored to your needs.\n\nHigh velocity systems – getting under the fire\n\nHigh velocity systems are often used to protect equipment that incorporate heavy or medium oils; equipment such as transformers, circuit breakers, diesel engines and fuel oil storage tanks, turbo alternator lube oil systems and oil fired boilers.\n\nThe high velocity nozzles are specifically designed to discharge a jet of water at high speed. The water jet forms a cone of coarse spray of uniform density which is discharged over a defined area. The coarse spray is able to penetrate the flame zone and reach the surface of the burning oil. The turbulence created by the high velocity spray forms an oil-in-water emulsion on the surface of the oil that will not burn. This “emulsification” is the principal way the fire is extinguished, along with a cooling and smothering effect.\n\nThe shape of the spray cone, the fire area contacted and the water flow is all controlled by the nozzle specifications – the orifice size and the shape of the internal swirl plate – along with the water pressure and the orientation of the nozzle.\n\nMedium velocity systems – cooling fire down\n\nMedium velocity sprayers discharge a water spray of finely divided droplets at medium velocity. They are ideal for protecting hazards involving light oils where emulsification from high velocity sprayers is not possible. The fine spray has a high heat absorption rate so medium velocity sprayers are an effective method of protecting adjacent plant and structures from heat during a fire by providing a continuous cooling spray over the exposed surfaces. Keeping nearby equipment cool minimises damage and reduces the risk of explosion.\n\nMedium velocity sprayers can be used in combination with other fire fighting systems – dry chemical and foam can be used effectively under the discharge. The fine spray also works to dilute and disperse flammable vapours. The sprayers use an external deflector to achieve the desired discharge angle and spray characteristics",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"hazard surface",
"specifically designed",
"spray cone",
"external deflector",
"effective method",
"orifice size",
"nozzle specifications",
"smothering effect",
"oilinwater emulsion",
"turbulence created",
"burning oil",
"flame zone",
"uniform density",
"incorporate heavy",
"individually tailored",
"transformer turbines",
"water pressure",
"water flow",
"spray characteristics",
"fine spray",
"coarse spray",
"water spray",
"defined area",
"protect equipment",
"special hazards",
"high speed",
"medium velocity",
"water jet forms",
"fire area contacted",
"continuous cooling spray",
"spray water directly",
"high velocity nozzles",
"high velocity systems",
"desired discharge angle",
"medium velocity sprayers",
"high velocity sprayers",
"oil fired boilers",
"medium oils equipment",
"combustible liquid hazards",
"disperse flammable vapours",
"protecting adjacent plant",
"finely divided droplets",
"internal swirl plate"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 7,
"imageuri": "https://bizimages.withfloats.com/actual/41c342e5fc2c4f0e958fe517ef02161b.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/41c342e5fc2c4f0e958fe517ef02161b.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:16:26.609Z",
"updatedon": "2025-05-07T13:16:26.609Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN/products/water-spray-systems/7",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Sprinkler System",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b5bdc4d3fb9d238d49d79",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Dry Sprinkler System",
"description": "A dry pipe sprinkler system is one in which pipes are filled with pressurized air or nitrogen, rather than water. This air holds a remote valve, known as a dry pipe valve, in a closed position. Located in a heated space, the dry-pipe valve prevents water from entering the pipe until a fire causes one or more sprinklers to operate. Once this happens, the air escapes and the dry pipe valve releases. Water then enters the pipe, flowing through open sprinklers onto the fire.\n\nAdvantages of using dry pipe fire sprinkler systems include:\n\nDry pipe sprinkler systems provide automatic protection in spaces where freezing is possible and water sensitive areas. Typical dry pipe installations include unheated warehouses and attics, outside exposed loading docks and within commercial freezers.\nThis perceived benefit is due to a fear that a physically damaged wet pipe system will leak while dry pipe systems will not. In these situations, however, dry pipe systems will generally not offer any advantage over wet pipe systems. Should impact damage happen, there will only be a mild discharge delay, i.e. 1 minute, while air in the piping is released before water flow.\n\nDisadvantages of using dry pipe fire sprinkler systems include:\n\nIncreased complexity – Dry pipe systems require additional control equipment and air pressure supply components which increases system complexity. Without proper maintenance this equipment may be less reliable than a comparable wet pipe system.\nHigher installation and maintenance costs – The added complexity impacts the overall dry-pipe installation cost. This complexity also increases maintenance expenditure, primarily due to added service labor costs.\nLower design flexibility – There are strict requirements regarding the maximum permitted size (typically 750 gallons) of individual dry-pipe systems. These limitations may impact the ability of an owner to make system additions.\nIncreased fire response time – Up to 60 seconds may pass from the time a sprinkler opens until water is discharged onto the fire. This will delay fire extinguishing actions, which may produce increased content damage.\nIncreased corrosion potential – Following operation, dry-pipe sprinkler systems must be completely drained and dried. Otherwise remaining water may cause pipe corrosion and premature failure. This is not a problem with wet pipe systems where water is constantly maintained in piping.\nWith the exception of unheated building spaces and freezer rooms, dry pipe systems do not offer any significant advantages over wet pipe systems.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 4,
"imageuri": "https://bizimages.withfloats.com/actual/8979708320c54b84abbfec64c2d74dd7.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/8979708320c54b84abbfec64c2d74dd7.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:10:52.668Z",
"updatedon": "2025-05-07T13:10:52.669Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN//dry-sprinkler-system/4",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Sprinkler System",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b6329f619d1f5f02ff84f",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "AMC ",
"description": "Well-maintained fire systems help save lives and property\n\nAs the risk of fire is always there, your fire suppression and detection systems need to be ready to perform when you need them most.\n\nThrough our regular maintenance services, our technicians aim to provide properly functioning fire equipment and systems. We service a huge range of fire protection systems for organizations large and small and can also maintain other manufacturers’ equipment.\n\nwe are ready to undertake emergency repairs and service calls to your fire-protection systems and products. Our teams can provide online support to the client’s facility team for all their service and breakdown call during emergency cases.\nSAFELINCS understands that when you have an emergency, time does not matter. Day or Night Technicians are on call, ready to be dispatched to handle your current crisis, with trained, experienced technicians.\n\nInspection and Testing\n\nToday, some of the largest and most successful companies in the world trust SAFELINCS to service and maintain their fire systems. Those same companies protect their most valuable assets and mission critical processes. In fact, over the past years, SAFELINCS’s service team has and continues to provide unmatched performance when it comes to Testing, Inspecting and Maintenance of your fire systems.\n\nFire Alarm and Detection System\nFire Suppression Systems\nHydrant System\nFire Pump Room Equipment\nFire Extinguishers\nSprinkler Systems\nEmergency/Exit Lights\nAccess Systems\nSurveillance Systems\nPublic Address Systems\nVESDA System\nRepair\n\nWhether a failure is uncovered during any routine inspection, or a system problem presents itself, SAFELINCS is committed to respond in a timely manner. SAFELINCS’s field technicians are trained to properly repair and maintenance your system to avoid future problems and future expenses.\n\nStrategically located field technicians for emergency response.\nOur Technicians have instant access to past inspection and maintenance history.\nSystem Recharge\n\nWhen your system discharges, protecting you from a fire, restoring your system is of the highest priority. SAFELINCS stands ready for a quick response and restoration of your suppression system.\n\nSystem Monitoring\n\nSAFELINCS offers fire alarm monitoring services to provide peace of mind to business owners who want a national team of monitors looking after life and property housed within the protected facility. In addition to fire alarms, SAFELINCS provides monitoring of supervisory signals for sprinkler malfunction and trouble signals indicating electrical malfunction. Alarm signals immediately prompt a dispatch call to the local fire department while personnel from the protected property and the alarm dealer are notified of supervisory and trouble signals. Records are maintained of all signals received and the state-of-the-art systems are tested regularly, inspected and maintained by SAFELINCS.\n\nTraining\n\nSAFELINCS provides site & system specific training for new installations. In addition, SAFELINCS has the expertise to provide training for older equipment still in service. In the event that new personnel or refresher training is required.\n\nTraining Topics may include:\n\nOverview of system components.\nUnderstanding of system application.\nSequence of operations.\nExplanation and differentiation of warning or alarm indicators.\nResetting and/or aborting functions.\nRoutine trouble shooting techniques.\nHow to call for service.\nSystem maintenance requirements.\nSafety considerations and issues.\nRecommendations for system improvement, if necessary\nModification\n\nWhen your existing space no longer meets your needs, SAFELINCS can modify your fire protection systems to meet you new requirements",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": null,
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 24,
"imageuri": "https://bizimages.withfloats.com/actual/d9697647bc7d401eb09efcc937a8d58c.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/d9697647bc7d401eb09efcc937a8d58c.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:42:01.786Z",
"updatedon": "2025-05-07T13:42:01.787Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN/products/amc-/24",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Services & Maintenances",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
},
{
"_id": "681b6220e66948a919653f2f",
"fptag": "SAFENGINEERINGLINCSSYSTEMPVTLT3424",
"merchantname": null,
"customwidgets": null,
"externalsourceid": null,
"name": "Fire extinguisher",
"description": "A Fire extinguisher is a device which can be used to control a fire. Fire extinguishers can help remove the fire, and may stop it from burning. Depending on the size, some fire extinguishers can be carried around and operated by hand. There are different kinds of fire extinguishers. Different kinds of fire can be controlled by different substances Classfication of Fire Extinguishers\n\nClass A fires involve organic solids such as paper and wood.\nClass B fires involve flammable or combustible liquids, including petrol, grease, and oil.\nClass C fires involve flammable gases.\nClass D fires involve combustible metals.\nClass E fires involve electrical equipment/appliances.\nClass F fires involve cooking fat and oil.",
"price": 0.0,
"discountamount": 0.0,
"currencycode": "INR",
"priority": 1000000,
"isfreeshipmentavailable": false,
"shipmentduration": 0,
"_keywords": [
"oil class",
"petrol grease",
"combustible liquids",
"substances classfication",
"burning depending",
"wood class",
"fire extinguishers",
"fire fire extinguishers",
"fire extinguishers class",
"fires involve flammable"
],
"isarchived": false,
"isavailable": true,
"applicationid": null,
"productindex": 23,
"imageuri": "https://bizimages.withfloats.com/actual/fb5de381b839453c898a577d35783fcf.jpg",
"tileimageuri": "https://bizimages.withfloats.com/actual/fb5de381b839453c898a577d35783fcf.jpg",
"images": null,
"totalqueries": 0,
"gpid": null,
"groupproductid": null,
"createdon": "2025-05-07T13:37:36.166Z",
"updatedon": "2025-05-07T13:37:36.166Z",
"buyonlinelink": null,
"producturl": "https://WWW.SAFELINCSINDIA.IN/products/fire-extinguisher/23",
"availableunits": -1.0,
"iscodavailable": false,
"isprepaidonlineavailable": true,
"maxcodorders": 0,
"maxprepaidonlineorders": 0,
"uniquepaymenturl": null,
"brandname": null,
"category": "Fire extinguisher",
"tags": null,
"variants": false,
"keyspecification": null,
"otherspecifications": null,
"pickupaddressreferenceid": null,
"paymenttype": "AssuredPurchase",
"producttype": "products",
"hsncode": "",
"gstslab": 0.001,
"isnotforsale": false
}
],
"hasmoreitems": false,
"isapirequest": false,
"totalresults": 24,
"query": null,
"floatingpoint": null
}